A Romanian engineering consultancy for advanced computing.

Kronsavier is an information-technology and infrastructure consultancy based in Bucharest. We specify, integrate and build computing systems across the full spectrum of scale — and we do it as engineers, not as resellers.

Our position is deliberately vendor-independent and standards-led. Every design is driven by the workload, the budget and the codes that govern real facilities — then tested rigorously, to audit standard, before anyone commits capital.

7

tiers of computing served — from desktop to supercomputer

1

partner, from requirement to working system

WHAT YOU SEEWHAT WE DESIGNNETWORKPOWERCOOLING
Head office
Bucharest, Romania
Discipline
IT & infrastructure consulting
Coverage
Equipment → servers → data centres → supercomputers
Position
Vendor-independent | standards-led | audit standard
Domains
HPC | AI training & inference | facility engineering
Full-spectrum practice

Credentialed across the whole technology life cycle.

IT & infrastructure consulting

Designing, integrating and operating computing environments and the resources that support them.

Data facility engineering

Electrical, cooling, fire & life safety, automation and commissioning.

HPC & AI cluster integration

Compute, interconnect, storage and scheduling, tuned to the workload.

Engineering & technical consulting

Electrical, thermal and mechanical engineering, plus specialist technical services.

Custom software & products

Bespoke software, tools productised, systems integration.

Applied R&D

Research, prototyping, benchmarking and performance engineering.

Testing, assurance & life cycle

Independent testing, commissioning, benchmarking; maintenance and refresh.

Managed operations & support

Monitoring, capacity management, updates, day-to-day operation.

Advisory, enablement & supply

Strategy, technical training, independent procurement, technical communication.

How we work

One engineering method, applied end to end.

  1. 01

    Assess

    Requirements, workload, constraints and budget — in plain language.

  2. 02

    Design

    Compute, network, power, cooling and space, sized together.

  3. 03

    Audit

    Independent review of specifications, TCO and safety claims.

  4. 04

    Build

    Procurement, integration and commissioning to specification.

  5. 05

    Operate

    Monitoring, tuning, efficiency and headroom for growth.

Independent & neutral

  • The right components, whoever makes them
  • We optimise for workload and budget

Audit-grade rigour

  • Specifications, TCO and safety claims
  • Tested line by line, before capital is committed

Fluent in the standards

  • Fire, thermal, electrical, resilience
  • Facilities that actually get built and certified
Standards & compliance

Built to the codes that matter.

We design to recognised international and Romanian standards — and document compliance as we go, so that an audit is a formality rather than an emergency.

ACTIVE PATHALTERNATE PATHCOMPONENTFIRE WALLITier IBASICCAPACITYIITier IIREDUNDANTCOMPONENTSIIITier IIICONCURRENTLYMAINTAINABLEIVTier IVFAULTTOLERANTLOADLOADLOADLOAD

Resilience & availability

How much downtime a facility can tolerate, and the redundancy that prevents it.

Uptime Institute | Tier
What they mean
Uptime Institute | Tier
The four-level scale (Tier I–IV) for how well a data centre keeps running through a fault or during maintenance.

Fire & life safety

Detecting and putting out a fire without endangering people or destroying the equipment.

NFPAClean agentEI classes
What they mean
NFPA
US fire-protection codes, used internationally for detection and suppression in data centres (e.g. NFPA 75 and NFPA 2001).
Clean agent
Gas suppression that puts out a fire without water and leaves no residue on the electronics.
EI classes
Fire resistance of walls and doors: how many minutes they hold back flames (E) and heat (I), e.g. EI 60.

Thermal & environmental

The temperature and humidity servers need to run reliably — and no colder than that.

ASHRAE TC 9.9
What they mean
ASHRAE TC 9.9
The ASHRAE committee whose guidelines set the recommended temperature and humidity ranges for IT equipment.

Electrical | ICT | quality

How the power, the cabling and the facility itself are designed, built and managed.

ENIECISO
What they mean
EN
European standards, including the EN 50600 series for data-centre design and operation.
IEC
International electrotechnical standards for installations and equipment, such as low-voltage systems and UPS units.
ISO
Management and quality standards: ISO 9001 for quality, ISO/IEC 27001 for information security, ISO/IEC 22237 for data centres.

Energy & efficiency

How much energy the facility uses, and how that is measured and reported.

EU EEDPUE / WUE
What they mean
EU EED
The EU Energy Efficiency Directive, which requires larger data centres to report their energy and water use.
PUE / WUE
Total energy (or water) divided by the energy the IT uses. A PUE close to 1 means little is lost to cooling and power conversion.

Romanian regulation

The national building, fire and energy rules a project must meet to be permitted and accepted.

National codesHG series
What they mean
National codes
Romanian technical norms for building services, e.g. I7 for electrical installations and P118 for fire safety.
HG series
Government decisions (Hotărâri de Guvern) with binding rules, for example on construction quality and the acceptance of works.

The frameworks shown illustrate our working practice; the applicable set is established per project and per jurisdiction.